1. Description

The high and low temperature ageing test of car display requires the use of a high and low temperature ageing chamber for car display, and the test method is based on the requirements of the "SJ/T 11272-2022 General Specification for Vehicle-mounted Colour Displays" standard. 

2. Test Equipment

Huanyi Instrument High and low temperature aging chamber for automotive displays Once this stage is complete, the display must be returned to room temperature and its appearance, structure, and performance must be checked to ensure it meets the established standards. This process ensures that the display maintains its integrity and functionality in a cold environment.

(1) Cold load test of high and low temperature ageing chamber

The low-temperature load test is similar to the low-temperature storage test. It requires the monitor to be operated in a low-temperature environment at -30°C. After 24 hours, the monitor is returned to room temperature and its appearance, structure, and performance are inspected. This test simulates the actual use scenario of the monitor under cold conditions, thus ensuring its reliability in the real world.

(2) High temperature storage test of high and low temperature ageing chamber

In the high-temperature storage test, displays are placed in an 80°C environment for 24 hours. Subsequently, the monitors must be inspected in terms of appearance, structure, and performance after being returned to room temperature.

(3) High temperature load test of high and low temperature ageing chamber

The high-temperature load test is a method for evaluating the performance of displays at a constant high temperature of 80°C. In this test, the monitor must be stored under high temperature for 24 hours and must also be able to work normally or bear loads under this environment. Once the test is complete, the display must be returned to normal temperature conditions and its appearance, structure and performance must be evaluated.
Should you require further information regarding the high and low temperature ageing chamber for car displays, we would be grateful if you could visit the official website of "Huanyi Instrument" and consult the relevant technical personnel.



Prev New Next New

Contact us

Telphone: +86 0769-83482055 / +8615338361334

Fax: +86 0769-83482056

Email: dg@huanyi-group.com

Add: Building 2, No. 3, Longkeng Xingye Road, Dongkeng Town, Dongguan,China

google+ twitter facebook printerest linkedin
Copyright 2018 by Dongguan Huanyi Instrument Technology Co., Ltd. All rights reserved. Powered by Onepound
Online Service
Top