High and low temperature environment test of tripod

Date: Jan 06,2022 Views: 217

The equipment used in the high and low temperature environment test of the tripod is a constant temperature and humidity test chamber. How should the high and low temperature humidity test be done for the tripod as a metal + plastic product? Let's take a look.

 

The high and low temperature environment test of the tripod is as follows:

 

1. Temperature lower limit test:

Put the sample into the test box (chamber) when it is not working, adjust the temperature in the test box (chamber) to 0°C, and after the temperature reaches a stable level, store the test sample for 2 hours, and the test sample should work normally. After the test is completed, wait for the temperature in the test box (chamber) to return to room temperature, and then take out the test sample.

 

2. Storage and transportation temperature lower limit test:

Put the test sample in the test box (chamber) with the smallest package, adjust the temperature in the test box (chamber) to -20, after the temperature reaches a stable level, store the test sample for 24h, take it out, and restore it under normal atmospheric conditions for 2h, test the sample Perform appearance and performance inspections in accordance with relevant requirements.

 

3. The upper temperature limit test:

Put the sample into the test box (chamber) when it is not working, adjust the temperature in the test box (chamber) to 40, and after the temperature reaches a stable level, store the test sample for 2h, and the test sample should work normally. After the test is completed, wait for the temperature in the test box (chamber) to return to room temperature, and then take out the test sample.

 

4. Storage and transportation temperature upper limit test:

Put the test sample into the test box (chamber) with the smallest package. Adjust the temperature in the test box (chamber) to 40. After the temperature is stable, store the test sample for 24 hours. After taking it out, place it under normal atmospheric conditions to recover for 2 hours. Appearance and performance inspections are required for relevant requirements.

 

5. Constant heat and humidity test

The test sample is in a bare metal state, put it into the test box (chamber), adjust the temperature in the test box (chamber), set the upper limit of the test box temperature to 40, relative humidity to 90%, and store it for 2h after the temperature is stable. The test sample should work normally. After the test is completed, wait for the temperature in the test box (chamber) to return to room temperature, and then take out the test sample.

 

6. Constant damp heat test under storage and transportation conditions:

Put the test sample in the test box (chamber) with the smallest package, adjust the temperature in the test box (chamber), set the test box temperature to 60, relative humidity to 93%, store it for 24h after the temperature is stable, and place it under normal atmospheric conditions after taking it out After 2 hours of recovery, the test sample shall be inspected for appearance and performance according to relevant requirements.

 

After passing the above high and low temperature test and damp heat test, if the product can be used normally, it means that the product is qualified in terms of environmental adaptability.




Prev New Next New

Contact us

Telphone: +86 0769-83482055 / +8615338361334

Fax: +86 0769-83482056

Email: dg@huanyi-group.com

Add: Building 2, No. 3, Longkeng Xingye Road, Dongkeng Town, Dongguan,China

google+ twitter facebook printerest linkedin
Copyright 2018 by Dongguan Huanyi Instrument Technology Co., Ltd. All rights reserved. Powered by Onepound
Online Service
Top