What test chamber is used for UL1642 battery testing?

The UL 1642 standard includes requirements for lithium battery testing, such as electrical performance testing, mechanical testing, and environmental testing of lithium batteries. Next, the huanyi instrument will give a brief explanation of the heating test and thermal cycle test in the environmental test.

 

1. Heating test:

The samples were heated in a natural convection or forced convection oven with an initial temperature of 20±5.

The oven temperature was raised to 130±2 at a rate of 5±2/min and kept for 10min.

The sample shall return to room temperature and the test shall be terminated.

Recommended test equipment: battery thermal abuse test chamber

Recommended Brand: Huanyi Instrument

Equipment features: simple and easy to use, fast air circulation.

 

2. Temperature cycle test:

a) Raise the temperature to 70±3 within 30min, and keep the temperature for 4h.

b) Cool the temperature to 20±3 within 30min and keep the temperature for 2h.

c) Cool down to -40±3within 30min and keep warm for 4h.

d) Raise the temperature to 20±3within 30min.

e) Repeat the above cycle 9 more times.

f) After 10 cycles, the battery is placed at room temperature of 20±5for 7 days for inspection.

 

The sample should not ignite, explode, leak or leak.

Recommended test equipment: battery thermal shock test chamber

Equipment model: HYQT series of huanyi instrument instruments

Equipment features: heating rate 5/min, 10/min, 15/min optional, to meet various test requirements.

 

The above is the explanation of the battery test requirements in UL 1642. If you want to know more about the test methods, you can visit the official website of "Huanyi Instrument" and consult relevant technical personnel.




Contact us

Telphone: +86 0769-83482055 / +8615338361334

Fax: +86 0769-83482056

Email: dg@huanyi-group.com

Add: Building 2, No. 3, Longkeng Xingye Road, Dongkeng Town, Dongguan,China

google+ twitter facebook printerest linkedin
Copyright 2018 by Dongguan Huanyi Instrument Technology Co., Ltd. All rights reserved. Powered by Onepound
Online Service
Top