Phone : +86 0769-83482055 / +8615338361334 Email: dg@huanyi-group.com
facebook twitter linkedin google+ printerest
You are here: Home > Technical Literature > Closed chamber evaporative emission SHED test chamber

Closed chamber evaporative emission SHED test chamber

Date: Mar 11,2024 Views: 36

Closed chamber evaporative emission SHED test chamber

 

1. Product introduction:

SHED closed evaporation test chamber is mainly used to measure the emission of fuel evaporation pollutants under the conditions specified by national/European/American standards and other regulations. The tests include: heat soak loss, refueling emission loss, and 24h/48h/72h daytime loss. . The temperature control range is +15~+60, which can simulate two modes of constant temperature and day and night temperature changes.

2. Meet test standards:

GB18352.3-2005 Light-duty vehicle pollutant emission limits and measurement methods (China III and TIV stages)

GB18352.5-2013 Light vehicle pollutant emission limits and measurement methods (China Phase 5)

GB18352.6-2016 Light-duty vehicle pollutant emission limits and measurement methods (China Phase Six)

T/CSAE 121-2019 "Test Method for Evaporative Pollutant Emissions from Non-Fuel Related Vehicle Parts and Materials"

European standard (Euro 6), American standard EPA (Code of Federal Regulations40O Part 86 (EPA Tier-I)) and American standard CARB (CCR Title13 (CARB LEV I-II)) related technical requirements.

3. Technical parameters:

Project

Require

Brand

HUANYI instruments

Volume inside the box

(1.0+0.02) m³

Dimensions

1200x1500x1550mm (length x width x height)

Adjustable range of temperature inside the test cabin

(15-40)

Internal relative humidity adjustable range

(30-60)%

Air flow rate inside the box

(0.1-0.3) m/s

Air replacement rate

(0.2-3) m³/h

Sealing

When there is an overpressure of 1000P8, the gas leakage is less than 10-3x1m³/min, and the gas flow difference between the inlet and outlet is less than 1%

Background concentration in the test chamber

Toxic acid 0.006mg/m³

Adiabatic

Climate chamber walls and doors should have effective thermal insulation

Noise

The noise when the climate box is working 60dB

Continuous working time

The climate chamber has a continuous working time of 28 days

Monitoring parameters

Monitor and display the temperature and humidity in the cabin, air supply and exhaust volume, power on and off time, working time, data can be transferred and stored

Humidity control method

The dew point control method is used to control the relative humidity of the working cabin. The humidity is stable, the fluctuation amplitude is <3%.rh, and no water droplets will be produced on the bulkhead.

 

4. The following factors ensure the reliability of the test:

Low background emissions significantly below legal specifications

Delivery of fully assembled systems

Short on-site installation and commissioning times

Determine the size of the test chamber according to the size of the sample (drive-in, walk-in, mini SHED, micro SHED, running loss SHED, drive-in (driving on a dynamometer)

If you have any questions about the selection of SHED closed evaporation test chamber, you can consult the relevant technical personnel of "Environmental Instrument".





Prev New Next New

Contact us

Telphone: +86 0769-83482055 / +8615338361334

Fax: +86 0769-83482056

Email: dg@huanyi-group.com

Add: Building 2, No. 3, Longkeng Xingye Road, Dongkeng Town, Dongguan,China

google+ twitter facebook printerest linkedin
Copyright 2018 by Dongguan Huanyi Instrument Technology Co., Ltd. All rights reserved. Powered by Onepound
Online Service
Top